Nortel DMS-100 Series Maintenance Manual page 536

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-170 Card replacement procedures
NT6X99
NT6X99
LCM
LCM
(continued)
(end)
6
7
8
9
10
11
297-8211-550 Standard 05.01 August 1999
Test the line card just replaced by typing
>DIAG
and pressing the Enter key.
If the DIAG
passed
failed
Return the line card to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 11.
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
You have successfully completed this procedure.
Do
step 7
step 10
Do
step 8
step 10