7-102 Alarm clearing procedures
RMM
minor
(continued)
5
6
7
8
297-8211-550 Standard 05.01 August 1999
To identify the LCM in the OPAC with links in a SysB condition, type
> TRNSL C
and press the Enter key.
Example of a MAP response:
LINK
0: LCM RLCM 00 0
LINK
1: LCM RLCM 00 0
To post the LCM in the OPAC identified in step 5, type
>POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the OPAC (alphanumeric)
frame
is the frame number of the OPAC (0 to 511)
lcm
is the number of the LCM
CAUTION
If you do not allow the time required for the system to
clear the alarm, a false alarm indication can occur.
Allow 3 to 5 min for the system to clear the alarm
before you proceed to the next step.
To identify the P-side links that have faults, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
LINK
0:
RMM 0 0;CAP
LINK
1:
RMM 0 1;CAP
LINK
2:
ESA 0 0;CAP
LINK
4:
ESA 0 1;CAP
To busy the link that has faults, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link that has faults identified by step 7.
0;CAP MS;STATUS:SysB,;MSGCOND:CLS
1;CAP MS;STATUS:
MS;STATUS:SysB,;MSGCOND: CLS
MS;STATUS:
OK,;MSGCOND: OPN
S;STATUS:
OK,;MSGCOND: OPN
S;STATUS:
OK,;MSGCOND: OPN
OK,;MSGCOND:OPN