Nortel DMS-100 Series Maintenance Manual page 42

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-26 Maintenance overview
The RMM can accommodate a maximum of 14 maintenance and service
circuit cards. These cards vary in type and meet different provisioning
requirements.
RMM connection with host and LCA through LCC
RMM shelf configuration
The RMM shelf has 20 slots. The HIE has 25 slots. The two slots on the far
left of the RMM (01, 02) are assigned to the DS30A interface and control
cards. Slots 17, 18 and 20 are on the far right of the shelf. These slots
contain two types of power converters required in the RMM.
The remainder of the shelf (slots 02 to 16) are assigned to service circuit
cards provisioned to meet office engineering requirements. The following
figure is an example of card selections for a normal RMM.
RMM control card
The RMM control card (NT6X74AB), located in slot 02, is required in the
RMM. The RMM control card acts as an interface between the LCA shelves
and the following:
The RMM control card processes DMS-X messages, trunk messages, and
pulse code modulation (PCM) data.
Power converters
Two types of power converters are required in the RMM shelf:
297-8211-550 Standard 05.01 August 1999
DS30A
link pair
DS-1 links
Host
test trunks of the RMM
service circuits of the RMM
alarm circuits of the RMM
multioutput power converter (NT2X09)
RMM
ESAP
DS30A
link pair
Link control
DS30A links
cards
LCA-0
LCA-1