Nortel DMS-100 Series Maintenance Manual page 453

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP terminal
8
Load the ESA processor by typing
>LOADPM
and pressing the Enter key.
If
The message loadfile not
found in directory is
received.
load passes
load fails
9
Determine the type of device on which the PM load files are located.
If load files are located on
tape
IOC disk
SLM disk
10
Locate the tape that contains the PM load files.
11
Mount the tape on a magnetic tape drive.
12
Download the tape by typing
>MOUNT tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape containing the PM load files
13
List the contents of the tape in your user directory by typing
>LIST T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape containing the PM load files
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Card replacement procedures 8-87
HIE
Do
step 9
step 26
step 29
Do
step 10
step 16
step 21
NT6X45
(continued)