Nortel DMS-100 Series Maintenance Manual page 229

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Recovering an out-of-service OPAC
16
CAUTION
Failure to allow enough time can cause false alarm
indication.
Allow 3 to 5 min for the system to clear the alarm
before you proceed to the next step.
To determine if the OPAC has emergency stand-alone (ESA), type
>QUERYPM
and press the Enter key.
Example of a MAP response:
PM Type: LCM
Memory Size: 64K
ESA equipped: Yes, Intraswitching is On
Loadnames: LCMINV – LCM33c ,Unit0: LCM33c ,Unit1: LCM33c
Node Status: (OK, FALSE)
Unit 0 Status: (OK, FALSE)
Unit 1 Status: (OK, FALSE)
Site Flr RPos Bay_id
TRLC
01
D04 RLCM 40
If OPAC
has ESA
does not have ESA
17
Manually check for dial tone at the remote to determine if the OPAC is in ESA.
A PM alarm that appears on the MAP screen indicates the OPAC is in ESA.
If the OPAC
has dial tone
does not have dial tone
18
Determine if the OPAC has the ESA timer set for manual recovery from ESA.
To access table OFCENG, type:
>TABLE OFCENG
and press the Enter key.
Int. No.: 20
Status index: 9
Shf
Description
04
LCM
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Recovery Procedures 6-9
Node_No: 165
Slot
40
0
Do
step 17
step 24
Do
step 18
step 24
(continued)
EqPEC
6X04AA