Nortel DMS-100 Series Maintenance Manual page 359

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Summary of ESA critical, minor alarm
At PM level of
MAP display,
display CBsy
ESA
Is ESA
CBsy?
N
Display SysB or
ISTb ESA
processor
Return ESA
processor to
2
service
Y
Post C-side
LCM
Post and busy
ESA processor
Y
Return to
service
passes?
N
Contact
maintenance
support group
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Alarm clearing procedures 7-123
critical, minor
This flowchart summarizes the
procedure.
Use the instructions that follow
this flowchart to perform the
procedure.
Display P-side
Busy and test
links that have
link that has
faults
faults
4
Test ESA
processor
End of
procedure
ESA
(continued)
6
1
Y
Test passes?
2
N
3