Nortel DMS-100 Series Maintenance Manual page 391

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8
Return to service the circuit tested by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
9
Place the untested circuit in the control position by typing
>NEXT 1
and pressing the Enter key.
10
Test the circuit by typing
>TST
and pressing the Enter key.
If TST
passed
failed
11
Return the circuit to service and clear the trunk test position by typing
>RTS;NEXT
and pressing the Enter key.
12
Send any faulty cards for repair according to local procedure.
13
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 15.
14
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
15
You have completed this procedure.
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Card replacement procedures 8-25
RMM
RMM
Do
step 9
step 14
Do
step 11
step 14
NT2X10
NT2X10
(continued)
(end)