12
To align RG activity to the new RG, type
>SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the LCM unit (0 or 1) associated with the new RG
Example of a MAP display:
LCM REM1 14 1 Unit 1 SWRG Passed
If the SWRG command
passes, and RG activity must switch
for the other unit
passes, and both units accept RG
activity
fails
13
Repeat step 12 for the other LCM unit.
14
To test the new RG, type
>TST UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the LCM unit (0 or 1) associated with the new
RG.
Example of a MAP response:
LCM REM1 00 0 Unit 1
LCM REM1 00 0 Unit 1
If TST
passes
fails
15
Repeat step 7 through step 14 for the other LCM unit.
InSvce Tests Initiated
Tst Passed
DMS-100 Family OPAC Maintenance Manual XPM12 and up