Nortel DMS-100 Series Maintenance Manual page 535

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X99 in an LCM
At your Current Location
1
Obtain a replacement card.
Ensure that the replacement card has the same product equipment code
(PEC), including suffix, as the card to be removed.
At the MAP terminal
2
Access the line test position (LTP) level of the MAP display and post the line
associated with the card to be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site rlcm lsg ckt
and pressing the Enter key.
where
site is the name of the site where the OPAC is located
rlcm is the number of the OPAC with the faulty card
lsg
is the number of the line subgroup with the faulty card
ckt
is the number of the circuit associated with the faulty card
Example of a MAP response:
LCC PTY
RNG .....LEN........
CKT TYPEFL
REM1 00 0 03 03
3
Check the status of the posted line.
If the line status is
manual busy (ManB)
not ManB
4
Busy the line by typing
>BSY
and pressing the Enter key.
5
Go to the procedure "Replacing a line card." When you have completed the
procedure, return here.
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Card replacement procedures 8-169
LCM
DN
STA F S LTA TE RESULT
IBERT
Do
step 5
step 4
NT6X99
(continued)