Nortel DMS-100 Series Maintenance Manual page 385

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

21
List the IOC file names into your user directory by typing
>LISTVOL volume_name
and pressing the Enter key.
where
volume_name is the name of the volume that contains the PM load files
obtained in step 19.
22
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
23
Go to step 28.
24
From office records, determine and note the number of the system load module
(SLM) disk and the number of the volume that contains the PM load files.
25
Access the disk utility level of the MAP display by typing
>DISKUT
and pressing the Enter key.
26
List the SLM file names into your user directory by typing
>LV CM;LF file_name
and pressing the Enter key.
where
file_name is the name of the SLM disk volume containing the PM load file
obtained in step 24.
27
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
28
Reload the RMM by typing
>LOADPM
and pressing the Enter key.
If
load failed
load passed
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Card replacement procedures 8-19
RMM
Do
step 32
step 29
NT2X09
(continued)

Advertisement

Table of Contents
loading

Table of Contents