Nortel DMS-100 Series Maintenance Manual page 423

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Summary of card replacement procedure for NT3X09 card RMM
At TTP level, post
the RMM
Is the RMM
status ManB?
Busy the trunks
associated with the
card
At PM level, post
and busy the
RMM
Y
N
Replace card with
one having
identical PEC
At PM level, post the
RMM and return it to
service
At TTP level, post
the RMM and return
trunks to service
End of procedure
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Card replacement procedures 8-57
RMM
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
NT3X09
(continued)