Nortel DMS-100 Series Maintenance Manual page 430

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-64 Card replacement procedures
NT6X17
LCM
(continued)
Replacing an NT6X17 in an LCM
At the MAP terminal
1
2
3
4
At the LCM
5
297-8211-550 Standard 05.01 August 1999
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
Access the line test position (LTP) level of the MAP display and post the line
associated with the card to be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site rlcm lsg ckt
and pressing the Enter key.
where
site is the name of the site where the OPAC is located
rlcm is the number of the OPAC with the faulty card
lsg
is the number of the line subgroup with the faulty card
ckt
is the number of the circuit associated with the faulty card
Example of a MAP response:
LCC PTY RNG .....LEN..........
1FR
REM1 00 0 03 03
Check the status of the posted line.
If the line status is
manual busy (ManB)
not ManB
Busy the line by typing
>BSY
and pressing the Enter key.
Go to the procedure replacing a line card. When you have completed the
procedure, return here.
DN
STA F S LTA TE RESULT
7213355
Do
step 5
step 4

Advertisement