Nortel DMS-100 Series Maintenance Manual page 454

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-88 Card replacement procedures
NT6X45
HIE
(continued)
14
15
16
17
18
19
20
21
22
23
297-8211-550 Standard 05.01 August 1999
Demount the tape drive by typing
>DEMOUNT T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
Go to step 25.
From office records, determine and note the number of the input/output
controller (IOC) disk and the name of the volume that contains the PM load
files.
Access the disk utility level of the MAP display by typing
>DSKUT
and pressing the Enter key.
List the IOC file names into your user directory by typing
>LISTVOL volume_name ALL
and pressing the Enter key.
where
volume_name is the name of the volume that contains the PM load files
obtained in step 16.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Go to step 25.
From office records, determine and note the number of the system load module
(SLM) disk and the name of the volume that contains the PM load files.
Access the disk utility level of the MAP by typing
>DISKUT
and pressing the Enter key.
List the SLM file names into your user directory by typing
>LV CM;LF file_name
and pressing the Enter key.
where
file_name
is the name of the SLM disk volume containing the file obtained
in step 21.

Advertisement

Table of Contents
loading