Nortel DMS-100 Series Maintenance Manual page 258

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-22 Alarm clearing procedures
LCM (RG)
critical
(continued)
8
9
10
11
297-8211-550 Standard 05.01 August 1999
To test the ManB LCM unit, type
>TST UNIT unit_no
and press the ENTER key.
where
unit_no
is the number of the ManB LCM unit (0 or 1)
If the system
generates a card list
does not generate a card list
Check the card list from step 8.
SITE
FLR RPOS
REM1
01
A00
REM1
01
A00
REM1
01
A00
REM1
01
A00
Determine if the NT6X60 card was replaced.
If you
replaced the NT6X60 card
did not replace the NT6X60 card
To return the LCM unit to service, type
>RTS UNIT unit_no
and press the ENTER key.
where
unit_no
is the number of the LCM unit (0 or 1) to be RTSed
If RTS
passes
fails
Do
step 9
step 18
BAY_ID
SHF DESCRIPTION SLOT
OPE 00
05
LCM:14 0
OPE 00
33
LCM:14 0
OPE 00
05
LCM:14 0
OPE 00
47
LCM:14 0
Do
step 18
step 17
Do
step 12
step 18
EQPEC
01
6X60
04
6X51
05
6X60
04
6X51

Advertisement

Table of Contents
loading

Table of Contents