193
Step 2
Configure parameters. See Table 4-61.
Parameter
Event Type
Enable
Less than
Alarm-out Port
Post-Alarm
Show Message
Report Alarm
Send Email
Copyright © NSS Sp. z o.o.
Figure 4-201
Table 4-61
Description
● Disk: Sets process method when there is a HDD event such as HDD
error, no HDD, no space.
● Network: Sets process method when there is a network event such
as disconnection, IP conflict, MAC conflict.
● Device: Sets process method when there is a device event such as
fan speed exception.
Different series products support different event types. The actual
product shall prevail.
Check the box to enable the function.
System generates an alarm once the HDD space is less than the
threshold.
For HDD No Space type only.
The alarm device (such as lights, sirens, etc.) is connected to the alarm
output port. When an alarm occurs, the NVR device transmits the alarm
information to the alarm device.
When the alarm ends, the alarm extended for a period of time. The time
range is from 0 seconds to 300 seconds.
Check box to enable a pop-up message in your local host PC.
Select the check box. When an alarm occurs, the NVR device uploads
an alarm signal to the network (including the alarm center).
● This function is for some series products only.
● You need to set the alarm center first. For details, see "1.11.13
Alarm Center".
Select the check box. When an alarm occurs, the NVR device sends an
email to the set mailbox to notify the user.
You need to set the email first. For details, see "1.11.10 Email".