2) Configure the parameters. See Table 4-36.
Parameter
Name
Action
Direction
Filter target
AI recognition
3) Press and hold down the left button on the monitoring screen to draw the
monitoring area.
4) Click OK to complete the rule setting.
Step 3
Click
Step 4
Select Enable check box and click Apply to complete the intrusion setting.

1.7.2.4.3 Abandoned Object Detection

System generates an alarm when there is abandoned object in the specified zone.
Figure 4-146
Table 4-38
Description
Customize the rule name.
Set the intrusion action, including appear and crossing area.
Set the direction to cross the area, including enter, exit and both.
Click
to filter the target. Check the blue wireframe and adjust the
size of the area with the mouse.
Each rule can set 2 target filters (maximum size and minimum size),
that is, when the passing target is smaller than the minimum target or
larger than the maximum target, no alarm will be generated. The
maximum size should not be smaller than the minimum size.
Select AI recognition and the system displays alarm target. The
default selection is person and motor vehicle and system
automatically identifies the person and motor vehicle appeared within
the monitoring range.
, you can refer to "1.7.2.4.1 Tripwire" to set other parameters.