People Retention Detection; Human Body Detection - BCS Line User Manual

Network video recorder
Table of Contents

Advertisement

User's Manual
Parameter
Duration
Repeat Alarm Time
Alarm People No.
Step 6
Click OK.

1.7.1.4.4 People Retention Detection

When the target stays beyond the set retention time threshold in the detection area, an alarm
will be triggered.
Step 1
Select Main Menu > AI > Parameters > Stereo Analysis.
Step 2
Select a channel and click Add.
Step 3
Select Enable and set Type to People Retention Detection.
Step 4
Click
Step 5
Configure parameters.
Parameter
Sensitivity
Duration
Repeat Alarm Time
Alarm People No.
Step 6
Click OK.

1.7.1.5 Human Body Detection

You can search the human body in videos and search the alarm record during the specified
period.
Step 1
Select Main Menu > AI > AI Search > Human Detection.
The Human Detection interface is displayed. See Figure 4-124.
Description
Set the minimum time of triggering an alarm when the number of
people reaches threshold.
Set repeat alarm time. If the alarm status continues, an alarm will
be trigger again when repeat alarm time is reached.
When the interval between people in the area is greater than or
equal to or less than the set interval threshold, an alarm will be
triggered.
, and then click and hold left mouse key to draw an area on the screen.
Table 4-33
Description
Set alarm sensitivity.
Set the minimum time of triggering an alarm when people stay in
the detection area.
Set repeat alarm time. If the alarm status continues, an alarm will
be trigger again when repeat alarm time is reached.
When the interval between people in the area is greater than or
equal to or less than the set interval threshold, an alarm will be
triggered.
114
Copyright © NSS Sp. z o.o.
114

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Line and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents