Case 580SR Service Manual page 165

Hide thumbs Also See for 580SR:
Table of Contents

Advertisement

www.maskinisten.net
Reset Mode:
When the microprocessor defaults to reset mode
both the T and N LEDs are displayed simultaneously
to indicate that a reset has taken place.
If no critical faults are active the microprocessor se-
lects N2 and goes to the Neutral lock state. See
"Driving with powershift" chapter.
Limp home function:
If a fault is detected at power-up, the limp home func-
tion is automatically selected.
IMPORTANT: if limp home is active, only 1st and
2nd gear will be selectable but without modulation.
The limp home function is active when the following
LEDs are on.
- Consult your Dealer.
LED - T
Flashing
Flashing
Flashing
Flashing
SECTION 21 - TRANSMISSION
LED - N
ON
Last fault currently shown on display
Slower flashing
Input error detected
Flashing in phase
Non-critical output error detected
Faster flashing
Safety critical output error detected
Copyright ©
CONDITION
99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

580sr+590sr695sr

Table of Contents