Case 580SR Service Manual page 960

Hide thumbs Also See for 580SR:
Table of Contents

Advertisement

www.maskinisten.net
132
Function Lamp
Air
conditionin
g not
functional
Hydraulic
filter
restriction
Fuel
contaminat
ed with
water
Fuel level
sensor
Fuel level
sensor
Fuel level
sensor
Transmissi
on
temperatur
e sensor
Transmissi
on
temperatur
e sensor
Transmissi
on
temperatur
e sensor
SECTION 55 - ELECTRICAL SYSTEM
Alarm
Lamp
Display
lamp
One second
alarm every
30 seconds
One second
alarm every
30 seconds
One second
alarm every
30 seconds
One second
alarm every
30 seconds
One second
alarm every
30 seconds
One second
alarm every
30 seconds
One second
alarm every
30 seconds
One second
alarm every
30 seconds
One second
alarm every
30 seconds
Condition
DTC
SA
Switch
closed to
1003 VCM
Vbat for 5
seconds
Switch
closed to
1004 VCM
ground for 5
seconds
Display
1022 VCM
message
Fuel sender
above 9 V for
1043 VCM
5 seconds
Fuel sender
below 0.5 V
1044 VCM
for 5 seconds
Input is
switched
1045 VCM
battery for 5
seconds
Transmission
temperature
sender above
1046 VCM
9 V for 5
seconds
Transmission
temperature
sender below
1047 VCM
0.5 V for 5
seconds
Input is
switched
1048 VCM
battery for 5
seconds
Copyright ©
Description Priority Color
Air
conditioning
4
Amber
system
pressure
Hydraulic filter
4
Red
threshold
4
Amber
Fuel sender
shorted high -
4
Amber
park gauge
Fuel sender
shorted low -
4
Amber
park gauge
Fuel sender
open circuit -
4
Amber
park gauge
Transmission
temperature
4
Amber
sender shorted
high
Transmission
temperature
4
Amber
sender shorted
low
Transmission
temperature
4
Amber
open circuit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

580sr+590sr695sr