Emf Setup Procedure - Keysight Technologies FieldFox A Series User Manual

Table of Contents

Advertisement

Over–the–Air Measurements (OTA) – LTE FDD Option 370 and 5GTF Option 377 (CPU2
Only)
How to Set Up EMF Settings (Requires EMF (Option 358))

EMF Setup Procedure

When the USB antenna correction factors are imported, EMF (Option 358)
couples many settings to ease setting up the EMF measurement (e.g.,
Apply Corrections is enabled, all X, Y, and Z antenna axes are enabled, and
Amp Corr Select is set to TriAxial XYZ).
1. Setup the FieldFox Spectrum Analyzer for a Channel Power measurement.
If necessary, this step can be skipped and done after the USB antenna is
set up.
2. Connect the USB antenna to the SA RF Input, port 2 and to a FieldFox USB
Only Agos Advanced Technologies SDIA–6000 Triaxial Isotropic USB
antenna is compatible with EMF (Option 358).
3. Importing and selecting X/Y/Z antenna factors:
If the antenna factor import is successful, the FieldFox displays: "Success: Antenna
Factors Imported: Tri-Ax Antenna ID: ->[R] Antenna ID:
SDIA-6000-1006 ->[]". The last 4-digits will vary for each antenna (i.e., "1006" is
changeable).
If the FieldFox displays this error Error: USB antenna Error: Not found or
Unable to communicate with antenna. Ensure it is connected. is
displayed, verify the USB antenna is connected correctly. Refer to
page 326
318
a. Press Mode >
OTA
Press Measure 1 then one of the following:
LTE FDD
5G TF
5G NR
5G NR EVM Conducted
port. See also,
Chapter 14, "USB Antennas – (Full Capability Requires EMF
Option 358, and SA mode (Option 233 Mixed Analyzers))"
14-1 on page
366.
Press System >
Utilities
— Press
Import Antenna
antenna's memory over the USB connection (this may take 5
seconds or so and vary with the Triaxial antenna).
.
— Press
USB Antenna
>
>
USB Antennas
to import the antenna factors from the
then:
Keysight N9927-90001 User's Guide
and to
Figure
"Troubleshooting" on

Advertisement

Table of Contents
loading