Display Line (I/Q, NF, and SA Modes Only)

A display line is a simple, horizontal line that can be placed at any amplitude level on the SA screen
or set to any level in IQA. Use a display line as mental guide for visual feedback. A display line is
similar to a Limit Line, except that no PASS/FAIL testing occurs. A display line is easier to create
than a Limit Line. Learn more in
Figure 28-8 Display Line with Annotations (SA mode shown, but others are similar)
How to create and move a Display Line
— Press Limit __8
— Then
Display Line OFF ON
— Then enter a Y-axis value using the
value using the numeric keypad and press a suffix key or press Enter.
Keysight N9927-90001 User's Guide
Data Analysis Features
All about Limit Lines
"All about Limit Lines" on page
arrows or the rotary knob, then press Enter. Or enter a
613.