Hydraulic oil tank breather / filler cap - cleaning
CAUTION
Flying debris!
Compressed air can propel dirt, rust, etc. into the air. Wear eye and face protection when using com-
pressed air.
Failure to comply could result in minor or moderate injury.
1. Move the machine to a level and firm surface.
2. Lower the loader attachment to the ground.
3. Place the backhoe attachment in the road travel posi-
tion.
4. Place the direction-of-travel lever and gearshift lever in
the neutral position.
5. Engage the parking brake.
6. Stop the engine and remove the starter switch key.
7. Release any possible residual hydraulic pressure by
moving the control levers in all directions.
8. Locate the wrench (1) supplied with the machine and
clean the area around the filler cap/breather.
9. Use the wrench (1) and remove the cap/breather (2).
10. Make sure that no dirt or foreign bodies enter the hy-
draulic oil tank.
11. Use a suitable grease solvent to wash the cap.
12. Leave the cap to air-dry.
13. Reinstall and tighten the cap (2).
7 - MAINTENANCE
7-62
C0049A
1
RAIL15TLB0082AA
2
RAIL15TLB0083AA