Normal engine starting
NOTICE: If the engine does not start within 30 s, allow the starter to cool for one minute and then begin the procedure
again.
1. Adjust the seat and fasten the seat belt.
2. Place the directional control lever in the NEUTRAL position.
3. Turn the engine hand throttle to the low idle position.
4. Turn the key switch to the ON position and wait for the engine pre-heat lamp to turn off.
5. Turn the key switch to the START position to actuate the starter motor.
6. If the engine starts and stops, do not actuate the starter motor again until the starter motor stops turning.
7. After the engine starts:
A. Check the instrument cluster to make sure that the gauge indications show normal operation.
B. Run the engine at 1000 RPM until the coolant temperature is warm.
4 - OPERATING INSTRUCTIONS