DLP-609: Inspect Optical Fiber(s)
....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
This procedure is used to correct an input or output fiber problem
such as a damaged or disconnected fiber.
Refer to the LambdaXtreme
System Turn-Up Services, Release 1.1, (365-575-782R1.1) and office
records to identify pre-installed and labeled fibers in the bay that
connect to various circuit pack slots.
CAUTION
SERVICE AFFECTING - This procedure could result in
service interruption.
............................................................................................................................................................
If required, remove the appropriate shelf covers. For details, go to
1
"DLP-607: Remove/Install Front Cover"
............................................................................................................................................................
2
Verify the fibers are properly connected.
............................................................................................................................................................
Visually inspect the fiber, starting at the connector on the local
3
network element and going as far as practical (usually to an
interconnection bay or to a cross-connect panel).
Look for any of the following problems:
•
Visible damage to the fiber
•
Excessive bends of kinks in the fiber
•
Damaged connectors
•
Improper/partial insertion of connectors
............................................................................................................................................................
Correct any problems with the fiber, following local procedures.
4
............................................................................................................................................................
Reinstall the shelf covers. For details, go to
5
Remove/Install Front Cover"
E
S
N D
O F
T E P S
.........................................................................................................................................................................................................................................................
Lucent Technologies - Proprietary
See notice on first page
™
Transport Installation Manual and
(7-17).
"DLP-607:
(7-17).
Detail Level Procedures
7 - 3 1
Need help?
Do you have a question about the LambdaXtreme and is the answer not in the manual?