Performance Parameters

OT Analog Parameters

....................................................................................................................................................................................................................................
Optical Power Received
Optical Power Transmitted
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
This is the amount of optical power being observed by the circuit
(OPR)
pack (OT) optical receiver. OPR is an internally monitored parameter
with factory -calibrated (non-provisionable) thresholds. During normal
operations, the parameter is measured regularly and reported as being
IN-RANGE or OUT-OF-RANGE. If the measured value is not within
the factory-specified operational range, then a TCA is raised.
Subsequently, if the value falls within the operational range, then the
TCA is cleared.
This is the amount of optical power being sent by the circuit pack
(OPT)
(OT) optical transmitter. OPT is an internally monitored parameter
with factory- calibrated (non-provisionable) thresholds. During normal
operations, the parameter is measured regularly and reported as being
IN-RANGE or OUT-OF-RANGE. If the measured value is not within
the factory-specified operational range, then a TCA is raised.
Subsequently, if the value falls within the operational range, then the
TCA is cleared.
Lucent Technologies - Proprietary
See notice on first page
Performance Monitoring
4 - 7