TAPs for the SLOT, SHELF, and FAN
Alarm Groups
TAP-104: Clear 'Network controller failure'
....................................................................................................................................................................................................................................
6 - 1 2
............................................................................................................................................................
Remove the FlashDisk from the slot in the NCTL circuit pack.
5
............................................................................................................................................................
Using both hands, remove the NCTL circuit pack.
6
............................................................................................................................................................
Obtain a replacement circuit pack with the same or higher series
7
number and, reinstall the FlashDisk removed in
replacement NCTL circuit pack.
Important! A series number S1:2 is the same series number as S1:4.
The 2 and 4 refer to minor changes within series 1.
............................................................................................................................................................
WARNING
Never install an NCTL circuit pack without a FlashDisk
present in the NCTL.
Install the replacement circuit pack (from
8
circuit pack with the lit FAULT LED. For details, go to
Remove and/or Install Circuit Pack"
............................................................................................................................................................
Wait approximately 15-20 minutes, depending on system size, or until
9
the MJ LED is off on the Office Alarms circuit pack (User Panel),
whichever comes first.
............................................................................................................................................................
Examine the
10
NE Alarm List
..........................................................................................................................................................
Is the alarm condition still listed?
11
IF...
YES
Lucent Technologies - Proprietary
See notice on first page
Step
7) in place of the
(7-20).
.
THEN...
Consult the appropriate maintenance
support organization for technical
assistance before with other trouble
clearing procedures.
Trouble Clearing Tasks
Step
5, into the
"DLP-608:
365-575-783R1.1
Issue 1, June 2002
Need help?
Do you have a question about the LambdaXtreme and is the answer not in the manual?
Questions and answers