Tap-111: Clear 'No Circuit Pack Expected In Slot - Lucent Technologies LambdaXtreme Alarm Messages And Trouble Clearing Manual

Table of Contents

Advertisement

TAPs for the SLOT, SHELF, and FAN
Alarm Groups

TAP-111: Clear 'No circuit pack expected in slot'

....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
6 - 3 0
This alarm condition is raised when a circuit pack is inserted in a slot
not meant for that type of circuit pack. For example, an OT in one of
the three slots assigned to an OA will cause this alarm condition.
............................................................................................................................................................
1
Examine the
NE Alarm List
............................................................................................................................................................
Using the
column, identify the appropriate shelf associated with
2
AID
the
No CP expected in Slot
............................................................................................................................................................
Remove the shelf cover. All connections can be accessed from the
3
front. For details, go to
(7-17).
..........................................................................................................................................................
Do office records or the LambdaXtreme
4
Manual and System Turn-Up Services, Release 1.1, (365-575-782R1.1)
show that the slot(s) should contain a circuit pack of this type?
IF...
YES
NO
............................................................................................................................................................
Reinstall the shelf cover. For details, go to
5
Front Cover"
(7-17).
............................................................................................................................................................
STOP! YOU HAVE COMPLETED THIS PROCEDURE.
6
Lucent Technologies - Proprietary
See notice on first page
.
alarm condition.
"DLP-607: Remove/Install Front Cover"
Transport Installation
THEN...
Check office records to determine
correct circuit pack or consult the
appropriate maintenance support
organization for technical assistance. If
a different circuit pack will be
inserted, continue with
Remove the circuit pack, then continue
with
Step
5.
"DLP-607: Remove/Install
Trouble Clearing Tasks
Step
7.
365-575-783R1.1
Issue 1, June 2002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LambdaXtreme and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents