TAPs for PortOA_RP and LINE Alarm
Groups
TAP-202: Clear 'DCM LOS'
....................................................................................................................................................................................................................................
6 - 5 0
............................................................................................................................................................
Reconnect the DCM.
10
............................................................................................................................................................
Reseat the OA circuit pack, and wait for it to boot. See
11
"Circuit Pack Warmup Times"
..........................................................................................................................................................
Examine the
NE Alarm List
12
IF...
YES
NO
............................................................................................................................................................
Replace the OA with a circuit pack of the same or higher series
13
number. For details, go to
Pack"
(7-20).
..........................................................................................................................................................
Examine the
NE Alarm List
14
IF...
YES
NO
............................................................................................................................................................
Remove the replacement circuit pack (installed in
15
reinstall the original circuit pack. For details, go to
Remove and/or Install Circuit Pack"
............................................................................................................................................................
Consult the appropriate maintenance support organization for further
16
technical assistance.
Go to
Step
22.
............................................................................................................................................................
Disconnect the fiber jumpers from the DCM, and measure the loss of
17
DCM.
Lucent Technologies - Proprietary
See notice on first page
(6-7).
. Has the alarm condition cleared?
THEN...
Go to
Step
22.
Continue with
Step
"DLP-608: Remove and/or Install Circuit
. Is the alarm condition still listed?
THEN...
Continue with
Step
Go to
Step
22.
(7-20).
Trouble Clearing Tasks
Table 6-1,
13.
15.
Step
13) and
"DLP-608:
365-575-783R1.1
Issue 1, June 2002