Lucent Technologies LambdaXtreme Alarm Messages And Trouble Clearing Manual page 183

Table of Contents

Advertisement

TAPs for the SLOT, SHELF, and FAN
Alarm Groups
TAP-116: Clear 'Circuit Breaker/Power
Failure "A or B" or "A and B"'
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
..........................................................................................................................................................
Was a problem found and corrected?
6
IF...
YES
NO
............................................................................................................................................................
CAUTION
Step 7
Replacing the wrong power filter will interrupt power to the
shelf providing service. The 48V power line filter associated
with the A feeder is located on the left; and the B feeder
power line filter is on the right. Verify the proper filter is
being used by checking the rear panel designations next to
the filters plug-in socket.
Contact Technical Support personnel to notify them you are about to
7
start replacing a power filter on a shelf.
............................................................................................................................................................
Replace the appropriate shelf power line filter. For details, go to
8
"DLP-610: Replace Power Line Filter"
..........................................................................................................................................................
Did the Circuit Breaker/Power "A or B" alarm condition clear?
9
IF...
YES
NO
............................................................................................................................................................
Consult the appropriate Technical Support organization for further
10
technical assistance.
............................................................................................................................................................
Reinstall the appropriate shelf cover. For details, go to
11
Remove/Install Front Cover"
E
S
N D
O F
T E P S
.........................................................................................................................................................................................................................................................
Lucent Technologies - Proprietary
See notice on first page
THEN...
STOP! YOU HAVE COMPLETED
THIS PROCEDURE.
Go to
Step
through
Step 9
requires replacement of a power filter.
THEN...
Continue with
Continue with
(7-17).
Trouble Clearing Tasks
10.
(7-32).
Step
11.
Step
10.
"DLP-607:
6 - 4 3