TAPs for SYSTEM and PortOther Alarm
Groups
TAP-610: Address 'Topology Construction In Progress'
....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
6 - 1 7 4
This is normally a transient condition, that appears while the OLS
Map is rebuilding. Follow the procedure below to Address it.
............................................................................................................................................................
Wait up to 30 minutes, depending on system size, or until the
1
CR/PROMPT, MJ/DEFERRED LEDs are extinguished.
............................................................................................................................................................
From the CIT
2
OLS Manager
Map
.
............................................................................................................................................................
At the CIT, initiate a login session to each node in the OLS Map.
3
............................................................................................................................................................
Examine the
4
NE Alarm List
..........................................................................................................................................................
Is the
5
Topology Construction In Progress
IF...
YES
NO
E
S
N D
O F
T E P S
.........................................................................................................................................................................................................................................................
Lucent Technologies - Proprietary
See notice on first page
, select any node and click on
.
condition still present?
THEN...
Clear that alarm, using the TAP listed in
Appendix A, "Alarm/Condition
STOP! YOU HAVE COMPLETED
THIS PROCEDURE.
Trouble Clearing Tasks
Retrieve
List".
365-575-783R1.1
Issue 1, June 2002