TAPs for the SLOT, SHELF, and FAN
Alarm Groups
TAP-109: Clear 'Circuit Pack Removed'
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
IF...
YES
NO
............................................................................................................................................................
From the CIT
6
Node Manager
associations related to the removed circuit pack.
............................................................................................................................................................
Select all the channels and delete the channels associated with the
7
removed circuit pack.
..........................................................................................................................................................
Has the alarm cleared?
8
IF...
YES
NO
............................................................................................................................................................
CAUTION
SERVICE AFFECTING - Failure to follow instructions in
this step could result in service interruption.
Notify the person that is responsible for the optical line associated
9
with the service to restore service on a different Optical Line System
or route, if available.
............................................................................................................................................................
Reseat the circuit pack or obtain a replacement circuit pack with the
10
same or a higher series number and install it in the empty slot. For
details, see
"DLP-608: Remove and/or Install Circuit Pack"
Lucent Technologies - Proprietary
See notice on first page
THEN...
Continue with
Step
9.
Continue with
Step
6.
, select all the channels, and remove the
THEN...
Continue with
Step
14.
From the office records, verify that the
channels and the corresponding OTs
are present.
Consult the appropriate maintenance
support organization for further
technical assistance.
STOP! YOU HAVE COMPLETED
THIS PROCEDURE.
Trouble Clearing Tasks
(7-20).