TAPs for OCHAN Alarm Group

TAP-404: Clear 'TCA optics: OCHAN (SPR-C)'

....................................................................................................................................................................................................................................
Overview
Before you begin
Display the default
threshold
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
The signal power received for a specific optical channel has either
exceeded the high threshold or has dropped below the low threshold.
Ensure the following:
Make sure there are no standing alarms that can attribute to the
TCA(s), for example, if there is an OCHAN TCA make sure that the
corresponding upstream add OT is not in alarm.
All TCAs have a default threshold value that was carefully chosen.
With the exception of OPR and OPT, all TCAs can be
user-provisioned.
If the TCA is occurring on more than one node associated with the
same channel/wavelength, start the following trouble-clearing process
at the first upstream node that is reporting the TCA. Fixing this node
first may very well clear the TCA at the other downstream nodes.
The following is the procedure for displaying the default
threshold:
............................................................................................................................................................
In the CIT, click on the
1
from the
Node Explorer
............................................................................................................................................................
Select the bay, shelf and slot/CP number.
2
............................................................................................................................................................
Click on
.
3
Select
Important! It can take as much as 10 minutes for a TCA to activate
or clear.
............................................................................................................................................................
4
Before taking the recommended action, check the sensitivity of the
current user-provisioned thresholds that can cause inadvertent
activation of TCAs, and only require adjusting the current threshold
value.
E
S
N D
O F
T E P S
............................................................................................................................................................
Lucent Technologies - Proprietary
See notice on first page
button, select an optical line
Performance
tree, and select the appropriate channel.
Trouble Clearing Tasks
6 - 1 2 3