Thresholds
Clearing QOS Alarms
....................................................................................................................................................................................................................................
clearHigh
clearLow
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
The clearHigh alarm-clearing threshold defines the value that the
gauge must reach in order to clear the QOS notification. This value,
when combined with the switch state, controls the clearing of the
notification. If notifyHigh's on/off switch is on and the gauge value
becomes equal to or less than the clearHigh's gauge value (in the
negative going direction) then the defined event notification is cleared.
Important! ClearHigh is non-provisionable and is fixed to be 10%
lower than the value of notifyHigh.
The clearLow alarm-clearing threshold defines the value that the
gauge must reach or exceed in order to clear the QOS notification.
This value, when combined with the switch state, controls the clearing
of the notification. If notifyLow's on/off switch is on, and the gauge
value becomes equal to or higher than notifyLow's gauge value (in a
positive going direction), then the defined event clearing is triggered.
Important! ClearLow is non-provisionable and is fixed to be 10%
higher than the value of notifyLow.
Lucent Technologies - Proprietary
See notice on first page
Performance Monitoring
4 - 2 3
Need help?
Do you have a question about the LambdaXtreme and is the answer not in the manual?