TAPs for the SLOT, SHELF, and FAN
Alarm Groups
TAP-110: Clear 'OMON Removed', 'SUPVY Removed'
....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
6 - 2 8
Use this procedure to clear one of these conditions by installing the
missing circuit pack.
•
OMON removed
•
SUPVY removed
............................................................................................................................................................
Examine the
NE Alarm List
1
obtain a snapshot.
............................................................................................................................................................
Using the
column from the report, identify the appropriate shelf
2
AID
associated with the removed circuit pack.
............................................................................................................................................................
Remove the appropriate shelf cover. All connections can be accessed
3
from the front. For details, refer to
Cover"
(7-17)).
..........................................................................................................................................................
Is the indicated slot empty or circuit pack unseated?
4
IF...
YES
NO
............................................................................................................................................................
Reseat an unseated pack, or install a replacement circuit pack, after
5
first making the proper fiber connections.
Important! Do not insert a circuit pack before making the proper
fiber connections.
..........................................................................................................................................................
Examine the
6
NE Alarm List
Lucent Technologies - Proprietary
See notice on first page
. You may wish to click on
"DLP-607: Remove/Install Front
THEN...
Continue with
Step
Consult the appropriate maintenance
support organization for further
technical assistance.
. Has the alarm cleared?
Trouble Clearing Tasks
Report
to
5.
365-575-783R1.1
Issue 1, June 2002