Performance Data Processing

Manual Baselining

....................................................................................................................................................................................................................................
Baselining Commands
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
The TL/1 threshold provisioning commands are:
SET-BASELINE-OCHAN for baselining analog parameters,
SPR-C and SPT-C
SET-BASELINE-OLINE for baselining analog parameters,
TOPT-OL and TOPR-OL
SET-BASELINE-SUPR for baselining analog parameter SPT-SU
The TL/1 retrieve commands used for retrieving the baseline values
are:
RTRV-BASELINE-OCHAN
RTRV-BASELINE-OLINE
RTRV-BASELINE-SUPR
Important! During initial installation, the baseline value for at least
one of the parameters SPR-C, SPT-C, TOPR-OL, TOPT-OL must be
established with an externally initiated user command. Once the
baseline value is established for at least one of the parameters, then
the other parameters will be automatically baselined for all existing
signal(s). Baselining is independent of external equipment, such as
when an Optical Spectrum Analyzer (OSA) is added or installed.