Tap-603: Clear Condition When 'Ne Acty/Info-N' Led Is Lit; Determine Command For Condition - Lucent Technologies LambdaXtreme Alarm Messages And Trouble Clearing Manual

Table of Contents

Advertisement

TAPs for SYSTEM and PortOther Alarm
Groups
TAP-603: Clear Condition When 'NE ACTY/INFO-N' LED is
Lit
....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
6 - 1 5 6
This procedure is used to clear one or more of the following
conditions:
Test alarm in progress
Flash memory module ready for removal
Inhibit alarms: office alarms
Logins inhibited
Provisioned control point
Provisioned environmental point
Important! The indicated condition was initiated by a user
command. You must determine, by consulting with the appropriate
maintenance personnel, whether the need for the user-initiated
condition still exists before proceeding.
............................................................................................................................................................
Does the need for the user-initiated condition still exist?
1
IF...
YES
NO
............................................................................................................................................................
Use the CIT to clear the indicated condition by performing the
2
function listed in
(6-157).
E
S
N D
O F
T E P S
............................................................................................................................................................
Lucent Technologies - Proprietary
See notice on first page
THEN...
STOP! YOU HAVE COMPLETED
THIS PROCEDURE.
Continue with
Table 6-2, "Determine Command for Condition"
Trouble Clearing Tasks
Step
2.
365-575-783R1.1