menu option on the Map window toolbar. This GUI window allows
you to:
provision facility and equipment alarm delays
provision facility and equipment alarm clearing delays
enable or disable audio/visual alarm indicators
allow or inhibit the receipt of autonomous messages
enable or disable alarm latching. When alarm latching is enabled
for an NE, an alarm is removed from the Alarm List only when
the following conditions are met: 1) the alarm is cleared 2) the
alarm is acknowledged. Alarm acknowledgement may be done
before or after the alarm is cleared. For Alarm Latching to be
enabled for an NE, Alarm Latching Readiness must be enabled
during installation of the LambdaXtreme
Latching Readiness is disabled, by default.