TAPs for the SLOT, SHELF, and FAN
Alarm Groups
TAP-106: Clear 'Fan failure'
....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
6 - 1 6
One or more of the fans have failed or the dust filter is clogged.
............................................................................................................................................................
Refer to the
AID
1
location of for the failed fan.
............................................................................................................................................................
Replace all dust filters in the bay with the alarm conditions. For
2
details, go to
"DLP-611: Inspect/Replace Air Filter"
............................................................................................................................................................
Important! Ensure that there is an available supply of replacement
fan assemblies.
Replace the fan assembly with a new one. For details, go to
3
"DLP-612: Replace Fan Assembly"
............................................................................................................................................................
Examine the
NE Alarm List
4
..........................................................................................................................................................
5
Referring to the report obtained in
listed?
IF...
YES
NO
E
S
N D
O F
T E P S
.........................................................................................................................................................................................................................................................
Lucent Technologies - Proprietary
See notice on first page
column of the
NE Alarm List
(7-37).
.
Step
THEN...
Consult the appropriate maintenance
support organization for further
technical assistance.
STOP! YOU HAVE COMPLETED
THIS PROCEDURE.
Trouble Clearing Tasks
and determine the bay
(7-34).
4, is the
Fan Failure
365-575-783R1.1
Issue 1, June 2002
still
Need help?