TAPs for PortOA_RP and LINE Alarm
Groups

TAP-208 Clear 'APR active: RPG Raman counter-pumps'

....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
6 - 6 2
This procedure is used to clear the
counter-pumps
raised as a result of lowering of the power of the copropagating
Raman pumps in RPG due to warmup or removal of the
corresponding RP. The power is lowered as a result of the detection of
one of the following alarms:
RP warmup in progress
RP removed
When these alarms are cleared, the
counter-pumps
............................................................................................................................................................
Examine the
NE Alarm List
1
IF...
YES
NO
..........................................................................................................................................................
Examine the
2
NE Alarm List
IF...
YES
NO
E
S
N D
O F
T E P S
.........................................................................................................................................................................................................................................................
Lucent Technologies - Proprietary
See notice on first page
APR active: RPG Raman
condition. This is a secondary condition which is
APR active: RPG Raman
condition will also clear.
. Is
RP warmup in progress
THEN...
Go to
"TAP-114: Clear
'OM/OD/OA/RP/RPG warm-up in
progress'"
Continue with
. Is
RP removed
THEN...
Go to
"TAP-109: Clear 'Circuit Pack
Removed'"
Consult the appropriate maintenance
support organization for further
technical assistance.
Trouble Clearing Tasks
listed?
(6-36).
Step
2.
listed?
(6-24).
365-575-783R1.1
Issue 1, June 2002