TAPs for OCHAN Alarm Group
TAP-405: Clear 'TCA optics: OCHAN (SPT-C)'
....................................................................................................................................................................................................................................
Overview
Display the Default
Threshold
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
The transmit signal power for a specific optical channel has either
exceeded the high threshold or has dropped below the low threshold.
Ensure the following:
Make sure there are no standing alarms that can attribute to the
TCA(s), for example, if there is an OCHAN TCA make sure that the
corresponding upstream add OT is not in alarm. All TCAs have a
default threshold value that was carefully chosen. With the exception
of OPR and OPT, all TCAs can be user-provisioned.
If the TCA is occurring on more than one node associated with the
same channel/wavelength, start the following trouble-clearing process
at the first upstream node that is reporting the TCA. Fixing this node
first may very well clear the TCA at the other downstream nodes.
The following is the procedure for displaying the default
threshold:
............................................................................................................................................................
Click on
Performance
1
............................................................................................................................................................
2
Select the bay, shelf and slot/CP number.
............................................................................................................................................................
Click on
3
OCHAN-( )e/w-( )
............................................................................................................................................................
Click on
Select
.
4
Important! It can take as much as 10 minutes for a TCA to activate
or clear.
............................................................................................................................................................
Before taking the recommended action, please check the sensitivity of
5
the current user-provisioned thresholds which can cause inadvertent
activation of TCAs, and, as a result, may only require adjusting the
current threshold value.