TAPs for PortOA_RP and LINE Alarm
Groups
TAP 213: Clear 'TCA optics: OLINE (TOPT-OL)'
....................................................................................................................................................................................................................................
Overview
Display the Default
Threshold
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
The total optical transmit power at the OA(VOA) has either exceeded
the high threshold or has dropped below the low threshold.
Ensure the following:
Make sure there are no standing alarms that can attribute to the
TCA(s), for example, if there is an OCHAN TCA make sure that the
corresponding upstream add OT is not in alarm.
All TCAs have a default threshold value that was carefully chosen.
With the exception of OPR and OPT, all TCAs can be
user-provisioned.
If the TCA is occurring on more than one node associated with the
same channel/wavelength, start the following trouble-clearing process
at the first upstream node that is reporting the TCA. Fixing this node
first may very well clear the TCA at the other downstream nodes.
The following is the procedure for displaying the default
threshold:
............................................................................................................................................................
From the CIT
1
Node Manager
either
Line 1E
or
............................................................................................................................................................
Click the
2
Performance
............................................................................................................................................................
Click on
.
3
Select
Important! It can take as much as 10 minutes for a TCA to activate
or clear.
............................................................................................................................................................
4
Before taking the recommended action, check the sensitivity of the
current user-provisioned thresholds that can cause inadvertent
activation of TCAs, and, may only require adjusting the current
threshold value.
E
S
N D
O F
T E P S
............................................................................................................................................................
Lucent Technologies - Proprietary
See notice on first page
, select the
Line 1W
.
button and select the
Trouble Clearing Tasks
tab, and select
Equipment
Analog Threshold
tab.
6 - 7 3
Need help?
Do you have a question about the LambdaXtreme and is the answer not in the manual?