Tap-207 Clear 'Apr Active: Rpg Raman Co-Pumps - Lucent Technologies LambdaXtreme Alarm Messages And Trouble Clearing Manual

Table of Contents

Advertisement

TAPs for PortOA_RP and LINE Alarm
Groups

TAP-207 Clear 'APR active: RPG Raman co-pumps'

....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
This procedure is used to clear the
condition. This is a secondary condition which is raised as
co-pumps
a result of lowering of the power of the copropagating Raman pumps
in RPG due to warmup or removal of the corresponding OA(VOA),
OA(Raman), OA(Raman EDFA), or OA(OADM LineOut). The power
is lowered as a result of the detection of one of the following alarms:
OA warmup in progress
OA removed
When these alarms are cleared, the
condition will also clear.
co-pumps
............................................................................................................................................................
Examine the
NE Alarm List
1
IF...
YES
NO
..........................................................................................................................................................
Examine the
2
NE Alarm List
IF...
YES
NO
E
S
N D
O F
T E P S
.........................................................................................................................................................................................................................................................
Lucent Technologies - Proprietary
See notice on first page
APR active: RPG Raman
APR active: RPG Raman
. Is
OA warmup in progress
THEN...
Go to
"TAP-114: Clear
'OM/OD/OA/RP/RPG warm-up in
progress'"
(6-36).
Continue with
Step
2.
. Is
listed?
OA removed
THEN...
Go to
"TAP-109: Clear 'Circuit Pack
Removed'"
(6-24).
Consult the appropriate maintenance
support organization for further
technical assistance.
Trouble Clearing Tasks
listed?
6 - 6 1