TAPs for PortOT Alarm Group
TAP-504: Clear 'Add side OC-48/STM-16
client synchronization failure'
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
............................................................................................................................................................
Initiate a Trouble Report to the source of the failed incoming signal
11
indicating the type of failure. If the source of the failed incoming
signal returns a Trouble Report indicating "no trouble found," then
continue with
Step
............................................................................................................................................................
STOP! YOU HAVE COMPLETED THIS PROCEDURE.
12
............................................................................................................................................................
CAUTION
SERVICE AFFECTING - Failure to follow instructions in
this step could result in service interruption.
Remove the OT identified in the
13
see
"DLP-608: Remove and/or Install Circuit Pack"
............................................................................................................................................................
CAUTION
The replacement OT must have the same (or higher) circuit
pack series number.
14
Obtain and install the replacement OT. For details, refer to
Remove and/or Install Circuit Pack"
..........................................................................................................................................................
Did the "Client Synchronization Failure" alarm condition clear?
15
IF...
YES
NO
............................................................................................................................................................
Remove the optical input jumper, reclean and reconnect it to the OT.
16
For details, refer to
Connectors"
(7-11).
Lucent Technologies - Proprietary
See notice on first page
13.
column in
AID
(7-20).
THEN...
Go to Step 24
Continue with
"DLP-606: Inspect and Clean Optical Fiber
Trouble Clearing Tasks
Step
1. For details,
(7-20).
"DLP-608:
Step
16.
6 - 1 4 1