TAPs for SYSTEM and PortOther Alarm
Groups
TAP-609: Clear 'Topology Construction Incomplete'
....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
6 - 1 7 2
Use this procedure to clear a node-to-node communication failure.
Important! When the network is in this state, you will probably not
be able to establish a login to one or more of the other nodes. If a
remote login is possible, and you need additional help, refer to the
section of the LambdaXtreme
Release 1.1, (365-575-781R1.1) detailing how to log in to a network
element. Otherwise, you will need local CIT assistance at those nodes.
............................................................................................................................................................
At the local NE CIT, examine the
1
..........................................................................................................................................................
Does the
NE Alarm List
2
(
Network controller failure
or an incoming alarm condition (
optical channels)
IF...
YES
NO
..........................................................................................................................................................
Using the office records for the network elements in the system, can
3
you establish a login to a remote node?
IF...
YES
NO
............................................................................................................................................................
Log in to any of the other network elements.
4
............................................................................................................................................................
Examine the
NE Alarm List
5
Lucent Technologies - Proprietary
See notice on first page
™
Transport User Operations Guide,
NE Alarm List
show a "controller" circuit pack condition
,
SUPVY failure
OSC LOS (opposite direction to
)?
THEN...
Clear that alarm, using the TAP listed in
Appendix A, "Alarm/Condition
Continue with
THEN...
Continue with
Go to
Step
8.
.
Trouble Clearing Tasks
.
, or
SUPVY removed
List".
Step
3.
Step
4.
365-575-783R1.1
Issue 1, June 2002
)