Tap-214: Clear 'Tca Optics: Supvy (Spt-Su) - Lucent Technologies LambdaXtreme Alarm Messages And Trouble Clearing Manual

Table of Contents

Advertisement

TAPs for PortOA_RP and LINE Alarm
Groups

TAP-214: Clear 'TCA optics: SUPVY (SPT-SU)'

....................................................................................................................................................................................................................................
Overview
Clear TCA optics: SUPVY
(SPT-SU)
....................................................................................................................................................................................................................................
365-575-783R1.1
Issue 1, June 2002
The power of the transmit supervisory signal has either exceeded the
high threshold or has dropped below the low threshold.
............................................................................................................................................................
Measure the power level to the IN_SUP port of the RP(OSP) circuit
1
pack.
..........................................................................................................................................................
Is the power level between –12 dBm and –15 dBm?
2
IF...
YES
NO
............................................................................................................................................................
Baseline the SUPVY. See
3
STOP! YOU HAVE COMPLETED THIS PROCEDURE.
............................................................................................................................................................
Replace the connector on the RP(OSP).
4
..........................................................................................................................................................
Examine the
NE Alarm List
5
listed?
IF...
YES
NO
E
S
N D
O F
T E P S
............................................................................................................................................................
Lucent Technologies - Proprietary
See notice on first page
THEN...
Continue with
Step
Go to
Step
4.
"Baseline the SUPVY (SUPT-SU)"
. Is
TCA optics: SUPVY (SPT-SU)
THEN...
Continue with
Step
Consult the appropriate maintenance
support organization for further
technical assistance.
STOP! YOU HAVE COMPLETED
THIS PROCEDURE.
Trouble Clearing Tasks
3.
(6-76).
still
3.
6 - 7 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LambdaXtreme and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents