TAPs for SYSTEM and PortOther Alarm
Groups
TAP-607: Clear 'SUPVY transmitting LOS'
....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
6 - 1 6 6
This procedure is used to clear an alarm condition where an RP circuit
pack detects loss of incoming SUPVY signal from SUPVY OUT port
to the RP IN_SUP port.
The alarm is raised when signal loss is detected at the IN_SUP port of
the RP circuit pack. This alarm is suppressed if there is a circuit pack
failure reported for either the RP or SUPVY circuit pack.
This alarm condition is caused by either of the following scenarios:
•
A problem with the connectivity between an OUT port on the
SUPVY circuit pack and the IN_SUP port of the corresponding
RP circuit pack.
•
A faulty LOS detector on the IN_SUP port of the associated RP
circuit pack
Important! A
SUPVY transmitting LOS
an
Incoming SUPVY channel LOS
the downstream NE.
............................................................................................................................................................
Examine the
NE Alarm List
1
............................................................................................................................................................
Remove the appropriate shelf cover. All connections can be accessed
2
from the front. For details, go to
Cover"
(7-17).
............................................................................................................................................................
CAUTION
SERVICE AFFECTING – This step could result in service
interruption.
Visually inspect the incoming signal cable(s) and connection(s)
3
between the SUPVY (OUT) and RP (SUP Rx) circuit packs and
Lucent Technologies - Proprietary
See notice on first page
alarm condition will cause
alarm condtion to be reported at
.
"DLP-607: Remove/Install Front
Trouble Clearing Tasks
365-575-783R1.1