TAPs for SYSTEM and PortOther Alarm
Groups
TAP-606: Clear 'OMON LOS'
....................................................................................................................................................................................................................................
6 - 1 6 2
..........................................................................................................................................................
Did the visual inspection result in correcting any problems?
6
IF...
YES
NO
..........................................................................................................................................................
Examine the
NE Alarm List
7
IF...
YES
NO
............................................................................................................................................................
Remove the fiber from the OMON port of the circuit pack identified
8
in
Step
2.
............................................................................................................................................................
Connect an optical power meter to the OMON port of the circuit pack
9
and obtain an optical power measurement
..........................................................................................................................................................
Is the power level greater than -37 dBm?
10
IF...
YES
NO
............................................................................................................................................................
Reconnect the fiber that was removed from the OMON port of the
11
circuit pack.
............................................................................................................................................................
Remove the fiber from the IN port of the OMON circuit pack that is
12
connected to the OA.
............................................................................................................................................................
Connect the optical power meter to the fiber just removed and obtain
13
a power measurement.
Lucent Technologies - Proprietary
See notice on first page
THEN...
Continue with
Step
Go to
Step
8.
. Is the same failure condition still listed?
THEN...
Continue with
Step
Go to
Step
28.
THEN...
Continue with
Step
Go to
Step
21.
Trouble Clearing Tasks
7.
8.
11.
365-575-783R1.1