Performance Data Processing

Analog Parameter Baselining

....................................................................................................................................................................................................................................
Overview
Automatic Baselining
Manual Baselining
....................................................................................................................................................................................................................................
4 - 1 4
Baselining is defined as measuring the current power level and saving
it as the expected nominal operational value for that parameter. The
purpose of a baseline value is to provide a basis from which to
measure deviation from nominal in the parameter value.
Baselining optical power levels is done automatically or through a
user command (Manual Baselining or Re-Baselining), and applies to
provisionable parameters.
Automatic Baselining establishes a reference power level for optical
analog parameters at the time of baselining. If necessary, these
parameters can be re-baselined manually using TL/1 commands
All provisionable analog parameters can be manually baselined
through the CIT, or with user-initiated TL/1 commands using the CIT
or the EMS interface.
Lucent Technologies - Proprietary
See notice on first page
Performance Monitoring
365-575-783R1.1
Issue 1, June 2002