15. Connect the I/O cables to the Stacker I/O PWB as follows:
P22 to J22A
P23 to J23A (connect to J23B if the Stacker has a Bypass
installed)
P24 to J24A (connect to J24B if the Stacker has a Bypass
installed)
P25 to J25A
16. Perform this step ONLY if a third party device is to be installed after
the stacker:
a. Check / move all Jumpers next to the DFA connector on the
Stacker I/O PWB so that they are connected JB to JC.
17. Connect the AC Power Cable from P14 on the to J14 on the Stacker
AC/DC Distribution PWB.
18. Connect the Punch Main AC Power Cable to the Punch.
19. Connect the Stacker Main AC Power Cable to the Stacker.
20. Plug each of the power cables into a wall receptacle.
21. Replace all covers on the Punch and Stacker.
22. Power up the Punch and check that the Bypass is Enabled (GP-1
Enter / Exit Diagnostics Mode Procedure).
23. Enter the Offline Mode.
24. Insert some paper into the Manual Paper Feed Tray to ensure correct
alignment and operation.
25. Ensure the correct host and personality profiles are enabled. Refer to
Section 6 General Procedures for more information.
Note: All down-steam devices must be set up for 6180 speed and must
use 6180 profiles regardless of what kind of Host Printer the devices are
connected to.
GBC FusionPunch II Service Manual
Installing a Second Offset Stacker
Prerequisite
Ensure that Stacker # 1 is equipped with a Bypass Assy. If the installed
stacker DOES NOT have a Bypass Assy installed, it has to be either;
a. upgraded with a Bypass Assy (0136100400 - Fusion Punch II
Domestic Bypass Kit, or 0136100500 - Fusion Punch II
International Bypass Kit) or;
b. un-installed and used as Stacker # 2 if the new stacker is
equipped with a Bypass Assy.
If neither of the these options are applicable, contact the sales
representative before continuing with the installation of Stacker # 2.
Installation
1. Complete the installation and alignment of stacker # 1 before
attempting this procedure.
2. Like attaching stacker # 1 to the punch, stacker # 2 is attached to
stacker # 1 by aligning the male docking pins on stacker # 2 docking
assembly with the female docking assembly on stacker # 1.
3. Mount the 2 locating pins on the top right side of stacker # 1. Move
stacker # 2 into position, close enough to stacker # 1 to adjust the
position of the locating pins on stacker # 1 with the holes in the frame
of stacker # 2 (Figure 8-6).