GBC FusionPunch II Service Manual page 114

With stacker and bypass
Hide thumbs Also See for FusionPunch II:
Table of Contents

Advertisement

REP 5.2 Bypass Assy removal
Parts List: 1.3 A
WARNING
Switch off the Main Power.
Disconnect the power cord.
Removal
1. Perform REP 5.5 Bypass Motor and Timing
Belt, Steps 1 to 4.
2. Remove the 2 Allen Head Cap screws and
2 Lock Washers holding the Bypass Motor
Assy (Figure 1). Place the Bypass Motor
Assy on the bottom of the Stacker.
3. Remove the two Allen Head Cap screws
holding the Bypass Gate Solenoid
connector and disconnect the Bypass Gate
Solenoid connector (Figure 3).
4. Remove the 2 Allen screws and the 2 Lock
Washers holding the Sensor Bracket
(Figure 2).
5. Gently move the Sensor Bracket and Exit
Sensor Assy to the side without unplugging
the Exit Sensor.
6. Remove the 2 Allen Head Cap screws, 2
Lock Washers and 2 Flat Washers holding
the Bypass Assy (Figure 3).
7. Gently lift out the Bypass Unit.
Replacement
1. Reinstall the parts in the reverse order.
2. Perform ADJ 5.5 Bypass Motor Timing Belt
Tension.
REP 5.2 Bypass Assy removal
Figure 1.
Figure 2.
12/2003
4-18
ALLEN HEAD CAP SCREWS (2)
LOCK WASHERS (2)
ALLEN HEAD CAP SCREWS (2)
LOCK WASHERS (2)
SENSOR
BRACKET